Stationary SIF camera for towers and fixed-point observation
- 660–790 nm
- 0.3 nm
- 1200
EnlargeLine-scan SIF camera: transmission grating, C-Mount, USB 3.0
FigSpec · CHNSpec · China
Line-scan SIF camera 660–790 nm: chlorophyll fluorescence in the field
Supplied with a 25 mm lens and a USB 3.0 cable. SIF retrieval needs incoming irradiance and reflectance-panel calibration; the manufacturer supports batch processing.
SIF is not reflectance but the plant's own chlorophyll glow — about 0.5–2 % of incoming radiation. The signal hides between the absorption lines of the atmosphere, so an ordinary hyperspectral camera is not enough: you need resolution in tenths of a nanometre and a low-noise detector. The FS-SIF-1A delivers 0.3 nm across 1200 bands at a signal-to-noise ratio of 600:1 — enough to resolve the fluorescence infill of those lines.
The camera is push-broom: it is carried by hand or mounted on a carrier, and the crop is scanned while moving. The primary product is SIF and, through it, gross primary production and ecosystem respiration — the carbon balance of the crop, not just the state of a single leaf.
| Spectral method | transmission grating |
|---|---|
| Spectral range | 660–790 nm |
| Spectral bands | 1200 |
| Spectral resolution (FWHM) | 0.3 nm |
| Slit width | 15 µm |
| Transmission | 60 % |
| Stray light | 0.5 % |
| Spatial pixels | 1920 |
| Pixel size | 5.86 µm |
| Capture rate | 128 fps across the full range, up to 3300 fps with ROI |
| Detector | CMOS |
| Signal-to-noise ratio | 600:1 peak |
| Interface | USB 3.0 |
| Lens mount | C-Mount |
| Lens | 25 mm, 25° field of view, other angles to order |
| Camera weight | 1.3 kg |
| Data formats | spe, hdr, scp; reflectance and area calibration, batch processing |
| Software | FIGSPEC UAV, MS-PreMerge, FIGSPEC Studio |
Specifications are given for a typical configuration and may differ for a specific delivery. Exact values are fixed in the commercial offer.
Frequently viewed with
Stationary SIF camera for towers and fixed-point observation
SIF system on board DJI M400: a canopy fluorescence map per field
Controlled-environment growth chamber with imaging modules
Request
Tell us what needs to be measured: crop, object, scale, budget. We will reply with configuration options and a commercial proposal.